FLOOR INSTALLATION

1. Make sure installation area is clean before starting.

DANGER!

HIGH VOLTAGE!! Disconnect and/or lock out the electrical supply to
the power unit prior to any maintenance being performed.

2. If the permanent electrical work is not complete, some means of temporary lines with

an on-off device for the power supply should be set up for testing purposes.

3. Place the Upender in the installation area.

CAUTION!

When moving the Upender, do not attempt to pick it up by the platform; it is
hinged and could be damaged. Pick up the Upender from under the base
frame ONLY using a strap sling.

4. Make temporary electrical connections and permanent hydraulic connections. Raise

the Upender approximately one foot using the “TILT” button. Then tilt it back fully,
holding the “TILT RETURN” button for approximately 60 seconds. Repeat this
process five to seven times to bleed any air out of the hydraulic system, alternating
directions each time.

5. Tilt the Upender to its fully tilted position then tilt return to ensure the tilt path is

unobstructed and that the Upender operates satisfactorily throughout its full travel.

DANGER

!

To avoid personal injury, NEVER go under the Upender platform until the
load is removed and the platform is securely blocked in position.