Installation instructions, Danger, Caution – Autoquip TITAN UPENDER User Manual

Page 15

Advertising
background image

15

6. The base frame of the Upender has pre-drilled holes for lagging it securely to the

floor. Mark the holes, drill, and install with anchors. Upenders with oversize
platforms have minimum pull out requirements of 2,000 lbs. for each anchor.

7. Make permanent electrical connections and operate the Upender through a few

cycles.

PIT INSTALLATION -- MODELS WITH BEVEL TOE GUARDS.

DANGER!

Do not install the Upender in a pit unless it has a bevel toe guard or other
approved toe protection. A shear point can exist which can cause severe
injury to the foot.

1. Check the pit dimensions. Length and width should be 2" minimum longer and wider

than the Upender platform.

2. Check the conduit chase entrance into the pit. The diameter should be 3". If the

permanent electrical work is not complete, some means of temporary lines with an
on-off device for the motor should be set up for testing purposes.

DANGER!

HIGH VOLTAGE!! Disconnect and/or lock out the electrical supply to
the power unit prior to any maintenance being performed.

3. Lower the Upender into the pit and check for proper height. The Upender should be

solid and flush with the pit angle framing. If needed, shim to the desired height.

CAUTION!

When moving the Upender, do not attempt to pick it up by the platform; it is
hinged and could be damaged. Pick up the Upender from under the base
frame ONLY using a strap sling.

INSTALLATION INSTRUCTIONS

Advertising
This manual is related to the following products: