WARNING! The velocity fuse must be installed
as illustrated. Never use a swivel fitting
between velocity fuse and cylinder. The
velocity fuse should always be attached to a
cylinder with a solid fitting.
Street Elbow 3/8 mp x 3/8 fp
Hex Nipple, Straight 3/8 mp x 3/8 mp
Velocity Fuse
Staight Swivel 3/8 mp x 3/8 fps
Braided High Pressure Hose
3/8-2W x 240", swivel (1) end.
Brass Elbow 3/8 tube flare x 3/8 mps
Push-on brass hose swivel
Low-Pressure Rubber Hose, 3/8" push-on
FLOW
CYLINDER HOSING
(Cut to length)
Figure 26 Cylinder Hosing