7. Tighten all 3 screws (3 Nm) so

that the power conductors are
held securely in place .

8. Check the U.L. strain relief

clamp to make sure that it is
tight and cannot be turned.

9. Replace the cover on the

terminal block and fasten in
place.

i

Make sure that the U.L. strain
relief clamp is outside the
cover!

The appliance is now ready to be
plugged into the 4Ćwire receptacle
of the power rating.

Connecting 3Ćwire power supply
cord

1. Remove the screws from the

cover of the terminal block
located at the top rear of the
appliance.

2. Make sure that there is

a grounding cable.

3. Loosen the 2 screws labeled L

and the screw labeled N in the
terminal block.

4. Attach the 2 power cord outer

conductors (red and black) to
the 2 terminals labeled L and
the remaining power cord
conductor (white) to the
terminal labeled N.

5. Tighten all 3 screws (3 Nm) so

that the power conductors are
held in place securely.

6. Check the U.L. strain relief

clamp to make sure that it is
tight and cannot be turned.

7. Replace the cover on the

terminal block and fasten in
place.

i

Make sure that the U.L. strain
relief clamp is outside the
cover!

Additional grounding procedure

-

Some local regulations may
require a separate ground.
In such cases, the required
accessory ground wire, clamp
and screw must be purchased
separately.

-

Never ground the dryer to
plastic plumbing lines, gas lines
or water pipes.

Grounding instruction

This appliance must be grounded.
In the event of a malfunction or
breakdown, grounding will reduce
the risk of electric shock by
providing a path of least resistance
for the electric current.
For Canada the dryer comes with a
cord which has an equipment
grounding conductor and a
grounding plug. The plug must be
plugged into an appropriate outlet
which has been properly installed
and grounded in accordance with
all local regulations and ordinances.

d

CAUTION

d

Improper connection of the
equipment grounding conductor
may result in electric shock.
Have the appliance checked by
a qualified electrician or service
technician if you are in doubt as
to whether the dryer has been
properly grounded.

Integrated socket

This appliance is equipped with a
socket for connecting a washer
without fuses. Only the listed
washer may be connected. For all
other connections Bosch will
assume no liability.

d

CAUTION

d

Use copper conducters only.

Connect to a 30 A minimum
individual branch circuit, fused at
30 A maximum.

Use receptable only for:
208 - 240 VAC 60 Hz 11 A
washer: WFR2460UC,
WFL2060UC.

Condensate hose
connection

The dryer must have its condensate
drain line installed and run to a
suitable drain.

The connection for the condensate
hose is located on the back of the
dryer.

Connect the condensate drain hose
to the dryer. The other end should
then be placed and secured at
nearby sink or drain.

If installed with a washer it may,
room permitting, be installed next to
the washer drain hose and drained
to the same drain used by the
washer.

Be sure to follow all local codes and
regulations in running the
condensate to a suitable drain.