to Enable Start Isolation*

1. Disconnect the black ground wire connected to the ML-ACR wire harness.

2. If present, disconnect all Start Isolation wires connected to the Brown, Green, and Orange wires in ML-ACR wire harness.

NOTE: This connection can be made at the start key switch or at the starter solenoid, but must be to the line that is +12V DC positive only when cranking. Connection to
a line that is positive while the engine is normally running will prevent the charging relay from working properly.

5. Re-connect the black DC Negative (Ground) wire in the ML-ACR wire harness

6. If connecting two ML-ACRs repeat steps 1 through 5 using the second ML-ACR, engine, and the P12 Battery Charger ports associated with ACR 2

4. Connect a wire from the ACR 1 terminal marked “ES” (Engine Start Switch) to the terminal or wire running from the start key switch to the starter solenoid.

NOTE: Connecting the “SI” (Start Isolation) wire to only one of the ML-ACR isolation wires will not properly integrate the P12 battery charger with your ML-ACR.

3. Connect a wire from the ACR 1 port marked “SI” (Start Isolation) on the P12 Battery Charger to both the Brown and Green wires in the ML-ACR wire harness.

23

DC GROUND

Temperature

Sensor

Remote

Display

ACR 1 ACR 2

SI: Start Isolation (ACR)

ES: Engine Start Switch

ES

SI

ES SI

Temperature

Sensor

Remote

Display

ACR 1 ACR 2

SI: Start Isolation (ACR)

ES: Engine Start Switch

ES

SI

ES SI

ENGINE

START

SWITCH

ON

OFF

START

ENGINE

START

SWITCH

A

B

ML-Series

Automatic

Charging

Relay

A

B

START ISOLATION #2 (GREEN)

ENGINE ISOLATION #3 (ORANGE)

START ISOLATION #1 (BROWN)

GROUND (BLACK)

ML-Series

Automatic

Charging

Relay

ISOLATION #2 (GREEN)

ISOLATION #3 (ORANGE)

ISOLATION #1 (BROWN)

GROUND (BLACK)

7520

BATTERY CHARGER LED REMOTE

OPTIONAL CONNECTION

OPTIONAL CONNECTION

START

HOUSE

START

ON

OFF

START

* The ML-ACRs also support “Engine Isolation” which
keeps an ACR open if two engines are running
simultaneously. Operating in this mode while using
Charger Coordination requires a special installation.
See bluesea.com/P12 for details.