Three wire range cord connection, Disconnect electrical power at breaker box – Bosch Dual-Fuel Slide-In Range User Manual

Page 17

Advertising
background image

Installation

English 15

Three Wire Range Cord Connection

The Four Wire Connection (above) is preferred, but where local codes and
ordinances permit grounding through neutral and where conversion to four wire is
impractical, the unit may be connected to the power supply via a three wire
connection.

1. Disconnect electrical power at breaker box.
2. Remove the terminal block cover to expose the terminal block.

3. Remove top nut, star washer, and round washer from each post.

4. Attach white wire, round washer, star washer and nut IN THIS ORDER on top

of ground strap on center post.

5. Attach red wire, round washer, star washer and nut IN THIS ORDER to left

post.

6. Attach black wire, round washer, star washer and nut IN THIS ORDER to right

post.

Figure 16: Terminal Block

Note:
DO NOT remove last round washer, last nut or internal wiring leads.

Figure 17: Three Wire Connection

red

white

black

ground strap

Advertising