Using the sensor band screw tightening sequence shown in Figure 9,
insert the sensor band spacer tool over the Belleville washers on the
middle sensor screw assembly and tighten it such that it is snug but
the spacer tool can still be removed. The following figure illustrates
use of the sensor band screw spacer tool.
Figure 10
Sensor Band Spacing Tool Installed on Sensor Screw
Note:
Ensure the spacer tool is perpendicular to the attachment rail to
ensure proper tightness. Remove the tool, move to the next sensor
screw, and repeat the tightening on each of the sensor screws.
Important:
Tighten each screw once only. Do not retighten each
screw using the gauge.
Final sensor band screw tightening is as follows:
A. For sensor bands sized for 6” and smaller pipe:
1. Tighten screws #1-7 an additional one-half turn in the numbered
sequence given in Figure 7. Do not tighten screw #8 & 9 (screws
on either end of the sensor band).
B. For sensor bands sized for 8” and larger pipe:
1. Starting at screw #1 in Figure 7, tighten each screw an additional
one-half turn in the given numbered sequence.
2. Once all nine screws have been tightened, tighten each screw an
additional one-half turn in the given numbered sequence.
3. Once all nine screws have been tightened a second time, tighten
screws #1-7 an additional one-half turn in the given numbered
sequence.
Attach the sensor cable in the retaining clip on the top of the sensor
band. The connector on this cable will attach to the sensor cover
Sensor screw spacing tool
installed on sensor screw
Sensor screw with
Belleville washers
compressed (typ)
Side view