6. Locate and drill one (0.228) diameter hole in flange

of sandplate to mount cable bracket.

7. Mount the lateral runout unit, guard, and wiring per

instructions in the 8113893 lateral runout kit.

8. Replace plastic A&D arm with new metal arm and

washer supplied in kit.

9. Replace main PCB with PCB supplied in kit.

Repack old PCB and return for credit.

10. Power up. Reset NOVRAM. Go to set up menus

and set all functions as desired. Turn printer function
ON. Check to make sure LED on front of printer blinks
every few seconds.

11. Perform machine self calibration with 4-oz.

weight and verify all functions.

12. Perform balance spin and follow instructions on

printer decal to check function of printer.

13. Follow instructions on lateral runout unit and go

to runout graph to verify function of lateral runout. Press
RIM, perform Rim Runout and check printer function
from this screen.