background image

775 - c1-t2 Wheel

- Measure the dimensions as shown in the following

diagram

Presetting:

nominal

Note: when dt2 is not set, dt2 = d + 2" is automatic.

Result of Measurement

After performing a balancing spin, the amounts of

unbalance are shown on the digital readouts.

Digital readouts with LED’s 3 - 4 lit up indicate the

correct angular wheel position to mount the counter-
weights (12 o’clock position).

In the event of unbalance less than the selected

threshold value

0

, is displayed in place of the unbal-

ance value, with

it is possible to read the

values below the selected threshold.

Note: In the event of wheels with diameter less than

or equal to 13" and at temperature conditions near 0˚,
the wheel balancer automatically engages a special
measuring cycle involving two successive measure-
ments. The precision of unbalance values and the reli-
ability of the wheel balancer are unaffected. This type
of operation is reset every time the wheel balancer is
started.

If at the end of any balancing run, the flashing symbol

appears, manually turn the wheel

until unbalances are displayed.

Recalculation Of The Unbalance

Press

after new setting of the measure-

ment.

Important: Always read and follow the instructions.

• 11

dc1

dt2

Ac1

At2

Hold down
3 seconds

Correction of inner side

Correction of outer side