Calibration – COATS 6450 3D User Manual

Page 23

Advertising
background image

Important: Always read and follow the information box instructions.

• 17

Calibration

Machine Calibration

Important: Use the correct calibration weight amount:

a 4-ounce calibration weight in ounce mode.

Important: The factory default is set for a 4-ounce

calibration weight amount for both ounce and gram

weight measurement modes. Therefore only a 4-ounce

calibration weight is necessary, regardless of weight

measurement mode setting.

Important: Before beginning calibration, be sure the

balancer is in fine balance mode by pressing the SHIFT

key and 6 to toggle to 0.01 oz. display mode; and bal-

ance the tire down below 0.20 oz.

1.

It is necessary to machine calibrate at least once in

both Truck and Car modes. Start calibration as follows:

Truck Mode - Hold SHIFT key and press 4 until

both Car Mode and Light Truck LEDs are toggled

off (both lights OFF IS Truck Mode). Then, mount a

R11 22.5 steer tire/wheel assembly on the balancer.

Note: Once both Truck and Car modes are initially cali-

brated, then it is only necessary to calibrate in the mode

that requires calibration. For example, if only truck tires

are balanced on this machine, then only the machine

calibration in Truck Mode is required.

Important: A balanced tire/wheel assembly is required.

Note: Position wheel so that no weights are on

either flange at the top-dead-center location. Turn the

machine OFF then ON.

2.

Hold SHIFT key and press 1 to select the CAL

MACHINE mode.

3.

Enter the D dimension.

4.

Lower the hood and press START.

5.

After spin, raise the hood. Attach calibration

weight to the outside flange at top-dead-center.

Figure 20 - Calibration Weight On Outside Flange At Top-Dead-
Center

6.

Lower the hood and press START.

Important: It is critical that the inner weight be

placed accurately to achieve proper calibration. If the

calibration weight is not moved from the outside flange

directly across to the inside flange, an inner weight

placement error will occur. To correct, follow the infor-

mation box instructions.

7.

After spin, raise the hood. Move and attach the cal-

ibration weight to the inside flange at top-dead-center.

Figure 21 - Calibration Weight Moved (Directly Across) To
Inside Flange

8.

Lower the hood and press START.

9.

Calibration complete. Press NEXT.

10.

After completing the Machine Calibration proce-

dure, the Arm Calibration will automatically initiate.

Arm Calibration

The Arm Calibration procedure begins immediately

after Machine Calibration.

During Machine Calibration, the balancer software

calculates both the A and W dimensions. The Arm Cali-

bration gives the balancer software a reference point

to the edge of the faceplate and home position. When

the user enters the A dimension from the arm rod, it

calculates the difference from the machine calibration

A and uses that as a factor for the manual A entry. Arm

calibration also gives the D dimension a reference point

from home position.

11.

Bring the tip edge of the arm precisely to the

outer edge of the faceplate and hold it there while

pressing the NEXT key. (If necessary to reach the

faceplate accurately, loosen the calibration wheel tem-

porarily.)