Ft cb 06 – Comelit FT CB 06 User Manual
Page 29
 
FT CB 06
27
FT CB 06
ENGLISH
* If the system is set with 6 digits it will be necessary to enter the number of the
block of flats before the user code EXAMPLE: 01 _ _ _ 1 (the block of flat num-
bers must have 2 digits as in the EXAMPLE)
4C) READING THE LIST OF NAMES (UPLOAD)
It is possible to read the list with the User name and code fields from module 3350
by means of software 1249/A.
INITIAL CONDITION
Module supplied 
in stand-by condition.
Connect the wire 
combined with Art. 1249/A
to terminals TX / RX / -.
Module 3350 must 
not be under
programming.
ENTER
TENANT CODE
4B) ENTERING A LIST OF NAMES BY MEANS OF SOFTWARE ART. 1249/A (DOWNLOAD)
It is possible to enter the list with the User name and code fields, in increasing
alphabetical order in module 3350 by means of software Art. 1249/A.
INITIAL CONDITION
Module supplied 
in stand-by condition.
Connect the wire 
combined with Art. 1249/A
to terminals TX / RX / -.
Module 3350 must 
not be under 
programming.
The directory must 
be empty.
ENTER
TENANT CODE
Press the ENTER key of
Art. 1230
Enter the user code
EXAMPLE: 1 *
Press the key ENTER of
Art. 1230 to store user
name and code.
It is possible to proceed to
enter other users.
ON DISPLAY
DESCRIPTION
OPERATION
CODE: _ _ _ _
CODE: _ _ _1
STORING IN
MEMORY...
Run software Art. 1249/A.
Consult the in-line 
Guide for the settings
required. 
Press the F7 key 
to start the download. 
On completion of the
download (disconnect 
the wire before starting 
to use the module).
If downloading is taking
place correctly.
If there are connection 
problems.
ON DISPLAY
DESCRIPTION
OPERATION
Or:
DOWNLOAD
FAILED
DOWNLOAD
COMPLETED