MINI-MAX Ultrasonic Bolt Tension Monitor

53

12) Use the UP and DOWN arrow keys to scroll through the sub menu

items until QUANTITY is highlighted.

13) Use the LEFT and RIGHT arrow keys to scroll the quantity options until

the ELONG option is displayed.

14) Press the MENU key multiple times to tab right and the ESC key

multiple times to tab left until the AUTO menu is highlighted and

displaying the submenu items.

15) Use the UP and DOWN arrow keys to scroll through the sub menu

items until APROX LEN is highlighted.

Note: This is the approximate physical length of the fastener or bolt. This

tells the MINI-MAX where to turn on the receiver and look for an echo. The

area scanned will be +/- 5% from the approximate length.

16) Press the ENTER key to display the Digits Edit Box.

17) Press the UP and DOWN arrow keys to scroll the highlighted value.

18) Press the LEFT and RIGHT arrow keys to scroll the digit locations.