Det-Tronics X7050 xWatch Industrial Video Surveillance Camera User Manual

Page 8

Advertising
background image

3.1

95-8600

6

WIrIng PrOCEDurE

CautIon

Power must not be applied to the device while
opening the housing or while plugging in or
removing the module.

1. Disassemble the enclosure by turning the housing

cover counterclockwise. See Figure 5 for an

illustration of the camera assembly.

2. Carefully remove the camera module.
3. Connect the external wiring to the screw connectors

marked A-, B-, C-, and D- on the camera terminal

block. See Figure 6.

Important

Do not test any wiring connected to the camera
with a meg-ohmmeter. Disconnect wiring at
the camera before checking system wiring for
continuity.

4. Check all field wiring to be sure that the proper

connections have been made.

5. Using the index pin as a guide, install the camera

module on the terminal block.

6. Re-assemble the device housing.
7. Make the final sighting adjustments and ensure that

the mounting bracket hardware is tight.

QUICK CONNECT PLUG (4)

POWER + (B)

VIDEO + (D)

POWER – (C)

VIDEO – (A)

A2365

INDEX PIN

Figure 6—xWatch camera Wiring terminal block

WIRING TERMINAL BLOCK

INDEX PIN

O-RING (2)

HOUSING COVER

CAMERA MODULE

TERMINAL CAP

A2366

QUICK CONNECT PLUG (4)

Figure 5—exploded view of xWatch camera

Advertising