Specifications

Alarm Type: Phone Call, SMS Text, Email, Audible
Ambient Operating RH Conditions : 0-95% RH non-condensing
Ambient Operating Temperature Conditions: -22 to 122F (-30 to 50C)
Antenna Type: External
Approvals: RoHS, FCC Part 15 Compliance, CE
Battery Life (Avg): 72 hours
Calibration Options: N100 , N300, N400, & N520
Channels: CH1: Temperature
Data Capacity: 32,000 (Backup)
Digital Display: Yes
Dimensions: 1.7 x 4.25 x 4.25in
Download Type: Wireless
Enclosure: Black; ABS Plastic Clam Shell
IP Rating: 21
Included Accessories: USB Cable, 4 AA Batteries, Replaceable Sensor
Mounting Options: Free Standing or Wall Mount (With Keyhole)
Note on Alarm Type: Alarms can be created for scenarios where the readings are outside a given range, communication
has been lost, or the batteries are low. All paid accounts are eligible to receive email and SMS text alarm notifications.
PC Requirements: DicksonOne.com can be accessed from any Windows, Mac, or Linux PC/Laptop using Google
Chrome, FireFox, Safari, or Internet Explorer 9. WiFi loggers need a Windows PC with .Net 4.0 or newer for initial
configuration. WiFi loggers are compatible with WEP, WPA, and WPA2 Personal security protocols.
Power Source: 120 to 240 VAC, 12 VDC (INTL fittings available)
Power Status Indicator: Red/Green/Blue (RGB) LED
Radio Frequency: 2.4 GHz
Remote Probe Dimensions : Houses thermistor sensor in polycarbonate plastic; 1.5" x 0.5" (1.25cm x 4.5cm)
Remote Sensor Length: Optional 10 ft extension cable (up to 3 extension cables can be added without sacrificing
accuracy)
Remote Sensor Type: 1 Field Replaceable Digital Temperature Sensor
Response Time: 30 Seconds to 63% of Full Scale
Sample Interval: User Selectable from: 60 seconds, 90 seconds, 2 minutes, 5 minutes, 10 minutes, 30 minutes, 1 hour
Software Options: All DicksonOne Data Loggers must be connected to a DicksonOne subscription to function correctly.
Storage Conditions: -22 to 122F (-30 to 50C)
Storage Conditions RH: 0-95% RH non-condensing
Temperature Accuracy: +/-1.2F from 20 to 122F 1.8F (+/-1C from -30 to 50C 1C)
Temperature Range: -22 to 122F (-30 to 50C)
Temperature Range Note: Range can be increased to -40 to 185F with use of extension cable
Temperature Sensor Type: Field Replaceable Digital Temperature Sensor
Unit Weight: 3 lbs
Units/Pkg: 1