Bosch Security Systems

Divar | Installation Manual | Menu system

EN | 5-15

>>> Output handling

•

Select the profile for which you wish to configure the output
handling.

•

Select the number of the output relays to be activated when an
enabled event in the selected profile is activated.

•

Enable the beeper to activate it when an enabled event in the
selected profile is activated.

>>> Recording setup

•

Recording behavior for each of the six profiles is specified in three
submenus. The Normal submenu is for a normal situation without
alarms or motion events. The Input submenu is for input changes.
The Motion submenu is for motion events.

•

The list gives an overview of inputs and motions that are used in
any of the profiles. A check mark means used.

Normal

•

Select the profile. The Unallocated IPS item shows the IPS
capacity remaining.

•

A total of 60 images per second (IPS) can be recorded for NTSC;
50 IPS for PAL. A minimum of 1 IPS is always allocated per
camera for pre-alarm recording and network viewing.

•

Set the recording rates and quality levels for each camera. Quality is
standard, medium or high.

•

IPS rates for PAL range from Never, 0, 1/10 (one image every 10
seconds), up to 25 IPS.

•

IPS rates for NTSC range from Never, 0, 1/10 (one image every 10
seconds), up to 30 IPS.

•

Set the recording speed to NEVER to not record a camera at all.
No pre-alarm recording is done and the camera cannot be viewed
over the network. No ATM/POS data is recorded.

Input

•

Each input, when activated, can change the normal recording
behavior of up to four cameras for a maximum of 120 seconds.

•

Select the profile. Select the input number.

•

Select the cameras whose recording behavior should change. Set
the recording rates and quality levels for each camera. Set camera
name to None to use less than four cameras.

•

To free IPS bandwidth, the recording rate of cameras not in alarm
is limited to the IPS number displayed.

Motion

•

Each motion input, when activated, can change the normal
recording behavior of up to four cameras for a maximum of 120
seconds.

•

Select the profile. Select the motion camera number.

•

Select the cameras whose recording behavior should change. Set
the recording rates and quality levels for each camera. Set camera
name to None to use less than four cameras.

•

To free IPS bandwidth, the recording rate of cameras not in alarm
is limited to the IPS number displayed.

>>> Access restrictions

•

Remote access restrictions can be set for each of the six profiles.

•

Select the profile. Select if local playback is enabled or not.

•

Select which remote users have access and which are blocked.

•

Remote user 1, the administrator, always has access.

>>> Copy system behavior

•

To copy the settings of one profile to another, enter the number of
the source profile, enter the number of the destination profile and
select the Copy Now item.