Vl logic supply(p2) – ElmoMC Gold Line Digital Servo Drives-Gold Drum Ver 1_400 D-Sub connectors User Manual
Page 28

Gold Drum (D-Sub Connectors) Installation Guide
MAN-G-DRUM(DTYPE)IG-EC (Ver. 1.400)
||VL Logic Supply(P2)
28
9.7. VL Logic Supply(P2)
Connect the VL Logic power supply as described below.
To connect the VL Logic supply:
1.
Use a 24 – 26 AWG twisted pair shielded cable. The shield should have braid and Drain wire.
2.
The source of the VL supply must be isolated from the Mains.
3.
Before applying power, first verify that the polarity of the connection is correct.
Figure 13: VL Logic Supply Connection Diagram
9.7.1.
VL Logic Supply(P2)
Pins
Signal
Function
Cable
7, 8
VL+
Positive input terminal of the logic (Control
& Encoders) power supply
VL Logic Supply Cable
9, 18
VL-
Negative (-) terminal of logic power supply VL Logic Supply Cable
Table 3: VL Logic Supply Pins and Polarity