Chapter 3: installation, 1 before you begin, 1 site requirements – ElmoMC Power Supplies-TAM-20 User Manual

Page 14: 2 hardware requirements, 1 ac input requirements, 2 recommended wire cross-sections (all models), Chapter 3, Installation, Before you begin 3.1.1, Site requirements

Advertising
background image

Tambourine 20 Power Supply Installation Guide

MAN-TAMIG (Ver. 1.501)

|Before You Begin|

www.elmomc.com

14

Table of Contents

Chapter 3:

Installation

This chapter describes the installation of the Tambourine 20 power supply.

3.1 Before You Begin

3.1.1

Site Requirements

You can guarantee the safe operation of the Tambourine 20 by ensuring that it is installed in an
appropriate environment.

Feature

Value

Ambient operating temperature

0 °C to 40 °C (32 °F to 104 °F)

Maximum non-condensing humidity

90%

Operating area atmosphere

No flammable gases or vapors permitted in area

Models for extended environmental conditions are available.

Caution

:

The Tambourine 20 dissipates its heat by convection. The maximum ambient

operating temperature of 0 °C to 40 °C (32 °F to 104 °F) must not be exceeded.

3.1.2

Hardware Requirements

3.1.2.1

AC Input Requirements

Circuit Breakers &

Contacts

Three-Phase Supply

Voltage

Single-Phase Supply

Voltage

Circuit breaker current rating 32 A Type D

40 A Type D

Circuit breaker voltage rating

250 VAC / 480 VAC depending upon operating AC voltage

Contactor

32 A

40 A

3.1.2.2

Recommended Wire Cross-Sections (All Models)

Feature

Connection

Details

AC input

AC1, AC2, AC3

2.5 mm

2

, 12 AWG

DC Output

VP+, VN-

2.5 mm

2

, 12 AWG

Protective earth

PE

2.5 mm

2

, 12 AWG