Tambourine 20 Power Supply Installation Guide
MAN-TAMIG (Ver. 1.501)
|Mounting and Wiring the Tambourine 20
22
3.4.4
Direct-to-Mains (No Isolation Transformer) Wiring Diagrams
Figure 3: Single-Phase Direct-to-Mains Connection
Caution
:
When using a single-phase AC source, terminals AC2 and AC3 must be paired
together in a shared connection.
Figure 4: Three-Phase Direct-o-Mains Connection