Connect cat5e wiring, N o t e – ETC Unison ERn Wall-mount Control Enclosure User Manual
Page 41
5
Install Rack Options
37
Connect CAT5e Wiring
Step 1:
Pull your CAT5e building wire through the conduit access previously prepared.
Step 2:
The punch down connector provides insulation displacement therefore stripping
of wire is not required. Reference the connector label for the color code for Cat5e
wire using the 568B standard.
Step 3:
Install the protective covers over the wire terminals.
Step 4:
Install the punch down connector on the patch panel.
Step 5:
Connect Ethernet patch cables.
a: Connect a patch cable from the left I/O to the first RJ-45 input on the Ethernet
Switch panel.
b: Connect a patch cable from the punch down connector to an RJ-45 input on
the switch panel. Repeat for each building service connection (up to four).
Step 6:
Install the Ethernet Switch Module into the enclosure and secure it in place using
the captured screws provided.
N o t e :
All Ethernet terminations must follow IEEE 802.3 and be terminated to the T568B
standard.
N o t e :
Use a 110 punch down tool to complete the wire termination.
As needed, press here gently
with screwdriver to release