The Retrofit

7

Step 6:

Unscrew and remove the plastic collars from around the termination buttons on

the new control panel circuit board.

Step 7:

Slide the new circuit board into the control input panel.

Step 8:

Secure the circuit board in place using the 8 screws for the DMX A and B

connectors.

Step 9:

Screw the plastic collars in place around the termination buttons.

Step 10: Connect the multi-colored DMX ribbon cable to the new circuit board.
Step 11: Connect the beacon connector red and

black twisted pair(s) to either the first or last

pair of the beacon header (shown here).

SP96 racks will use both pairs.

Step 12: If your rack has a neon indicator to the right of the control inputs, this is a “second

fan indicator”. If yours is not labeled, place the label found in the kit (7143A4001)

above the neon indicator.

Use either pair

DMX Cable

Connection

Beacon Wires