Technical data – EUCHNER N1A Single hole fixing limit switch User Manual

Page 6

Advertising
background image

Operating Instructions Precision Single Limit Switches N

1

A

Technical data

Parameters

Value

Housing material

Die-cast aluminum, anodized

Plunger material

Stainless steel

Degree of protection
acc. to IEC 60529

IP 67

Mechanical operating cycles

ES502E / ES508E

30x10

6

ES514

1x10

6

ES588

1x10

6

Switching frequency

ES502E

300 min

-1

ES508E / ES514

50 min

-1

ES588

20 min

-1

Ambient temperature

ES502E

-5 ... + 80 °C

ES508E / ES514 -25 ... + 80 °C
ES588

-25 ... + 70 °C

Installation position

Any

Approach speed, max.
Plunger Chisel D

40 m/min

Roller R (slide bearing)

80 m/min

Roller B (ball bearing)

120 m/min

Dome W/ball K

10 m/min

Extended roller

20 m/min

Approach speed, min.

0.01 m/min

Actuating force

ES502E

≥ 20 N

with switching element

ES508E

≥ 15 N

ES514

≥ 30 N

2 x ES588

≥ 20 N

Switching element
ES502E

1 NO + 1 NC

ES508E

1 positively driven contact

ES514

1 NO + 1 positively driven
contact

ES588

1 positively driven contact

Switching principle
ES502E / ES514

Snap-action switching contact

ES508E / ES588

Slow-action switching contact

Hysteresis

ES502E

0.8 mm

ES514

0.6 mm

Contact material
ES502E / ES508E / ES514

Silver alloy, gold flashed

ES588

Fine silver

Connection type
N1A...M

Screw terminals

N1A...SVM5...

Plug connector M12

Conductor cross-section

0.34 ... 1.5 mm

2

Rated insulation voltage
with cable entry

U

i

= 250 V

with plug connector

U

i

= 50 V

Rated impulse withstand voltage
with cable entry
ES502E/ES508E/ES514

U

imp

= 4 kV

ES588

U

imp

= 2.5 kV

with plug connector

U

imp

= 2.5 kV

Utilization category switching element according to IEC 60947-5-1
ES502E

AC-12 250 V

10 A

ES502E / ES508E

AC-15 230 V

6 A

DC-13

24 V

6 A

ES514

AC-15 230 V 2.5 A
DC-13

24 V

6 A

ES588

AC-15 230 V

4 A

DC-13

24 V

3 A

Switching current,
min.,

at 24 V DC

ES514

5 mA

ES508E

10 mA

at DC 12 V

ES502E

10 mA

at DC

5 V

ES588

1 mA

Conv. thermal current I

th

10 A

Short circuit protection according to ES502E/ES508E/
IEC 60269-1 (control circuit fuse) ES588

10 A gG

ES514

6 A gG

Rated short-circuit current

100 A

Indicator LED

LE060

AC/DC 12 - 60 V

(only with ES502E / ES508E)

LE110

AC 110 V ±15%

LE220

AC 220 V ± 15%

Reliability figures according to EN ISO 13849-1
for switching elements

ES508E
ES588

ES514

B

10d

2 x 10

7

2 x 10

6

Figure 6: Dimension drawing N1A... with plug connector M12

35

33

20

M12x1

Figure 8: Connector assignment plug connector M12

1

2

4

3

5

2

1

3

4

5

21

13

22

14

2

1

3

4

5

21

13

22

14

2

1

3

4

5

21

13

22

14

N1A.502SVM5-M

N1A.SVM5-MC1883

N1A.514SVM5-M

Pin layout plug connector SVM5
(view on switch)

Figure 7: Plungers and approach directions

D

R

B

W

K*

RL

Chisel

Roller

Roller

Dome

Ball

Extended roller

Slide bearing

Ball bearing

(* only with switching element ES502E)

Preferred approach directions

120°

-5°

Advertising