14 troubleshooting and assistance, 1 fault reset, 2 help on troubleshooting in the internet – EUCHNER MGB-L0-xxxAPx-xxx User Manual
Page 32: 3 help on mounting in the internet, 15 service, Troubleshooting and assistance, Fault reset, Help on troubleshooting in the internet, Help on mounting in the internet

32
Operating Instructions MGB-L0...AR.-... and MGB-L0...AP.-...
14 Troubleshooting and assistance
14.1 Fault reset
Proceed as follows:
1. Switch off the operating voltage at the interlocking module for min. 3 sec-
onds. As an alternative, 24 V can be applied to the input RST for min. 3
seconds.
¨
The green LED (State) flashes quickly (approx. 5 Hz). A self-test is performed
during this time (MGB-...AR approx. 8 s). The LED then cyclically flashes three
times.
2. Close safety guard and insert bolt tongue.
¨
The system is in normal mode again.
14.2 Help on troubleshooting in the Internet
You will find a help file on troubleshooting in the download area at www.EUCHNER.de.
14.3 Help on mounting in the Internet
You will find an animation on the mounting process at www.mgb.EUCHNER.de.
15 Service
If service support is required, please contact:
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
D-70771 Leinfelden-Echterdingen
Service telephone:
+49 711 7597-500
E-mail:
[email protected]
Internet:
www.euchner.de