Operating Instructions MGB-L0...AR.-... and MGB-L0...AP.-...

5 Function

Together with a handle module, the interlocking module makes it possible to inter-

lock movable safety guards. The combination also serves as a mechanical door

stop at the same time.
The following switch-on condition applies for the safety outputs FO1A and FO1B

(see also sections 13.2 System status table MGB-AR, page 30 and 13.3 System

status table MGB-AP, page 31):

Configuration

System family

MGB-AR

MGB-AP

Condition

Not a fault in the device

TRUE

TRUE

Safety guard closed

TRUE

TRUE

Bolt tongue inserted in interlocking module

TRUE

TRUE

In case of series connection:

Signal available from the upstream switch on the safety

inputs FI1A and FI1B

In case of separate operation:

DC 24 V available on the safety inputs FI1A and FI1B

TRUE

Not relevant

FO1A and FO1B are ON

The interlocking module detects the position of the safety guard and the position

of the bolt tongue.
The bolt tongue in the handle module is moved into and out of the interlocking

module by actuating the door handle.

DIP

OFF

ON