Operating Instructions MGB-L0...AR.-... and MGB-L0...AP.-...
5 Function
Together with a handle module, the interlocking module makes it possible to inter-
lock movable safety guards. The combination also serves as a mechanical door
stop at the same time.
The following switch-on condition applies for the safety outputs FO1A and FO1B
(see also sections 13.2 System status table MGB-AR, page 30 and 13.3 System
status table MGB-AP, page 31):
Configuration
System family
MGB-AR
MGB-AP
Condition
Not a fault in the device
TRUE
TRUE
Safety guard closed
TRUE
TRUE
Bolt tongue inserted in interlocking module
TRUE
TRUE
In case of series connection:
Signal available from the upstream switch on the safety
inputs FI1A and FI1B
In case of separate operation:
DC 24 V available on the safety inputs FI1A and FI1B
TRUE
Not relevant
FO1A and FO1B are ON
The interlocking module detects the position of the safety guard and the position
of the bolt tongue.
The bolt tongue in the handle module is moved into and out of the interlocking
module by actuating the door handle.
DIP
OFF
ON