Operating Instructions Safety System CES-AZ-UBS-01B
28
Read head CES-A-LMN-SC
Ì
Cylindrical design M12
Ì
M8 plug connector (snap-action and screw terminals)
Dimension drawing
Note
The read head is allowed to be installed as a maximum up to the clear zone (area 
of the active face without metal housing).
Typical operating distance
With evaluation unit CES-AZ-UBS-... and actuator CES-A-BMB
Note
A minimum distance of s = 1.2 mm must be maintained.
Approvals
17
5
32
19,
7
s
m
35
4
8
30
M1
2
x1
M8
x1
37
1)
1)
Reading distance
Centr
e of
fset
connected
Active face
1) Clear zone (area of the active face without metal housing)
2
4
6
6
8
8
X
8
6
4
2
2
4
6
8
8
6
Y
Z