Operating Instructions Safety System CES-AZ-UBS-01B
3
Correct Use
The Coded Electronic Safety switches series CES are safety devices for monitor-
ing movable safety guards.
In combination with a separating safety guard and the machine control, this safety 
component prevents dangerous machine movements from occurring while the 
safety guard is open. A stop command is triggered if the safety guard is opened 
during the dangerous machine function. 
Before safety switches are used, a risk assessment must be performed on the 
machine in accordance with:
Ì
EN ISO 13849-1, Safety of machinery. Safety related parts of control systems. 
General principles for design
Ì
EN ISO 14121-1, Safety of machinery. Risk assessment. Principles
Ì
IEC 62061, Safety of machinery – Functional safety of safety-related electrical, 
electronic and programmable electronic control systems.
Correct use includes compliance with the relevant requirements for installation 
and operation, in particular
Ì
EN ISO 13849-1, Safety of machinery. Safety related parts of control systems. 
General principles for design
Ì
EN 1088, Safety of machinery. Interlocking devices associated with guards. 
Principles for design and selection
Ì
EN 60204-1, Safety of machinery. Electrical equipment of machines. General 
requirements
Ì
EN 60947-5-3 Specification for low-voltage switchgear and controlgear. Con-
trol circuit devices and switching elements. Requirements for proximity devices 
with defined behavior under fault conditions (PDF)
The following components can be connected to the evaluation unit CES-AZ--UBS...:
Ì
CES read heads
Ì
CEM read heads
Ì
CET read heads
For further information, refer to the operating instructions of the corresponding 
component and to the following table Possible combinations for CES components.
Important!
Ì
The devices permit a safety-related stop function, initiated by a safety guard 
according to Table 8 - DIN EN ISO 13849-1: 2008-12.
Ì
The safety-related function of the PDF is the opening of the output 
contacts (13/14, 23/24) when the actuator is absent.
Ì
The user is responsible for safe integration of the device in a safe overall 
system. For this purpose, the overall system must be validated, e.g. in ac-
cordance with EN ISO 13849-2.
Ì
The permissible operating parameters must be observed for correct use 
(see Technical Data).
Ì
If a product data sheet is included with the product, the information on the 
data sheet applies in case of discrepancies with the operating instructions.
Ì
Only components may be used that are permissible in accordance with the 
table below.