System manual safety system ces-a-s5h01, Truth table, Pulse diagram – EUCHNER CES-A-S5H-01 (Unicode) User Manual
Page 20
Advertising

System Manual Safety System CES-A-S5H01
0
Truth table
Actuator
Safety outputs
Data outputs/LED displays
LA
LB
D3
D
D1
D0
No actuator
0
0
0
0
0
0
Safety actuator
1
1
0
0
0
1
Actuator
0
0
0
0
1
0
Actuator 3
0
0
0
0
1
1
Actuator 4
0
0
0
1
0
0
Actuator 5
0
0
0
1
0
1
Actuator 6
0
0
0
1
1
0
Actuator 7
0
0
0
1
1
1
Actuator 8
0
0
1
0
0
0
Actuator 9
0
0
1
0
0
1
Actuator A
0
0
1
0
1
0
Actuator B
0
0
1
0
1
1
Actuator C
0
0
1
1
0
0
Actuator D
0
0
1
1
0
1
Actuator E
0
0
1
1
1
0
Actuator F
0
0
1
1
1
1
Pulse diagram
Transponder
Nr.
in the
operating
distance
Yes
No
Safety
outputs
LA, LB
ON
OFF
Position actuator
4
7
8
1
Safety actuator
Time t
200 ms
4 … 9 ms
200 ms
< 200 ms
30 … 180 ms
30 … 180 ms
Monitoring
outputs
D3
D2
D1
D0
ON
OFF
ON
OFF
ON
OFF
ON
OFF
t
t
t
t
t
If a new transponder enters the operating distance
within the switch-off delay, the switch-off delay
is interrupted and the new transponder number
signaled.
Advertising