System manual safety system ces-a-s5h01, Typical operating distance, Operating distance for center offset m = 0 – EUCHNER CES-A-S5H-01 (Unicode) User Manual
Page 27: Operating distance at read distance s = 6 mm

System Manual Safety System CES-A-S5H01
7
Typical operating distance
Only in combination with actuator CES-A-BBA or CES-A-NBA
Operating distance for center offset m = 0
1)
Parameter
Value
Unit
min.
typ.
max.
Assured switch-on distance S
ao
18
-
-
mm
Switch-on distance
-
0
-
Switching hysteresis
3
-
Assured switch-off distance S
ar
-
-
40
1) The values apply for surface installation of the actuator.
Operating distance at read distance s = 6 ... 10 mm
1)
Parameter
Value
Unit
min.
typ.
max.
Side operating point on center
offset
± 10
± 14
-
mm
Switching hysteresis
0,3
0,7
-
1) The values apply for surface installation of the actuator.
X
25
15
20
10
5
20
25
30
5
10
15
-30
30
-30
25
20
15
10
5
Y
Z
For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm
must be maintained so that the operating distance of the side lobes is not entered.