Bryant 559F User Manual

Page 2

Advertising
background image

—

2

—

LEGEND

MM — Motormaster® Head Pressure Control Device

*Use the 32LT900301 for 208/230 units. Use the 32LT900611 for 460-v

units.

†Not required on models with the loss-of-charge switch on the liquid

line.

LEGEND (FIG. 1-16, 20 AND 21)

LOWER OUTDOOR AMBIENT OPERATION ACCESSORIES

Unit

559F/

579F

Std Min.

Operating

Temp

Mild Ambient Control

Low Ambient Control

Min.

Operating

Temp (F)

Acy Kit Part No.

Required (Quantity)

Accessory

Name

Wiring

Fig.

No.

Min.

Operating

Temp (F)

Acy Kit Part No.

Required (Quantity)

Accessory

Name

Wiring

Fig.

No.

Sensor

Location

Fig. No.

180

40

10

CRWINSTR001A00,

CRLOWAMB001A00

Winter Start Kit

10 F Ambient Kit

22,23

–20

CRWINSTR001A00,

CRLOWAMB001A00,

32LT900301

OR

32LT900611*†

Winter Start Kit,

10 F Ambient Kit,

–20 F MM I

22,23,

24

25

216

40

10

CRWINSTR001A00† (2),

CRLOWAMB001A00

Winter Start Kit

10 F Ambient Kit

22,23

–20

CRWINSTR001A00 (2),

CRLOWAMB001A00,

32LT900301

OR

32LT900611*†

Winter Start Kit,

10 F Ambient Kit,

–20 F MM I

22,23,

24

25

240

40

25

CRWINSTR001A00,

CRLOWAMB002A00

Winter Start Kit

25 F Ambient Kit

22,26

–20

CRWINSTR001A00 (2),

30GT910079††

Winter Start Kit,

–20 F MM III

22,27

28

300

40

25

CRWINSTR001A00,

CRLOWAMB002A00

Winter Start Kit

25 F Ambient Kit

22,26

–20

CRWINSTR001A00 (2),

30GT910079††

Winter Start Kit,

–20 F MM III

22,27

28

AHA

— Adjustable Heat Anticipator

BR

— Burner Relay

BRK W/AT

— Breaks With Amp Turns

C

— Contactor, Compressor

CAP

— Capacitor

CB

— Circuit Breaker

CC

— Cooling Compensator

CH

— Crankcase Heater

CLO

— Compressor Lockout

CLS

— Compressor Lockout Switch

COMP

— Compressor Motor

CPM

— Compressor Protection Module

CR

— Control Relay

CT

— Current Transformer

DM

— Damper Motor

DU

— Dummy Terminal

EAS

— Economizer Actuator

Auxiliary Switch

EMC

— Economizer Motor Contactor

EQUIP

— Equipment

FL

— Fuse Link

FLA

— Full Load Amps

FPT

— Freeze-Protection Thermostat

FS

— Flame Sensor

FU

— Fuse

GND

— Ground

GVR

— Gas Valve Relay

HC

— Heater Contactor

HPS

— High-Pressure Switch

HS

— Hall Switch

HTR

— Heater

HV

— High-Voltage

I

— Ignitor

IDM

— Induced-Draft Motor

IFC

— Indoor (Evaporator) Fan Contactor

IFCB

— Indoor (Evaporator) Fan

Circuit Breaker

IFM

— Indoor (Evaporator) Fan Motor

IFR

— Indoor (Evaporator) Fan Relay

IGC

— Integrated Gas Controller

L

— Light

LED

— Light-Emitting Diode

LLS

— Liquid Line Solenoid

LOR

— Lockout Relay

LPS

— Low-Pressure Switch

LS

— Limit Switch

MAT

— Mixed-Air Thermostat

MGV

— Main Gas Valve

NEC

— National Electrical Code

NEUT

— Neutral

OAT

— Outdoor-Air Thermostat

OFC

— Outdoor (Condenser) Fan Contactor

OFM

— Outdoor (Condenser) Fan Motor

OP

— Overcurrent Protection

PL

— Plug Assembly

PRI

— Primary

QT

— Quadruple Terminal

RS

— Rollout Switch

SEN, SN — Sensor
SR

— Solenoid Relay

SW

— Switch

TB

— Terminal Block

TC

— Thermostat Cooling

TH

— Thermostat Heating

TRAN

— Transformer

U

— Unloader

UR

— Unloader Relay

Terminal (Marked)

Terminal (Unmarked)

Terminal Block

Splice

Splice (Marked)

Factory Wiring

Field Control Wiring

Field Power Wiring

Accessory or Optional Wiring

To indicate common poten-
tial only, not to represent
wiring.

Advertising