As-i safety monitor for 2 as-i circuits, Spezifications, Safety monitor block diagram: connections – EUCHNER AS-i Safety Monitor for 2 AS-i circuits User Manual
Page 17

AS-i Safety Monitor for 2 AS-i circuits
Spezifications
Subject to reasonable modifications due to technical advances
Id.-No.: 103336
Issue date - 24.10.2008
EUCHNER GmbH + Co. KG
17
Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen
Tel. +49/711/75 97-0 • Fax. +49/711/753316
103303
Electrical data
Operating voltage
24 V DC (26,5
…
31,6 V out of AS-i)
Operating current
approx. 200 mA out of 24 V
DC
and approx. 45 mA out of AS-i
Standards
EN 61 000-6-2, EN 61 000-6-4
EN 62 061, SIL 3
EN 61 508, SIL 3
EN 13 849, performance level e
Housing
stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 85 / 96
Protection category (IEC 60 529)
IP20
Tolerable loading referring to impacts
and vibrations
according to EN 61 131-2
Weight
800 g
Safety Monitor block diagram:
Connections:
Sicherheitsmonitor
(Safety Monitor)
1.Y1 (EDM 1 / Start 1)
2.Y1 (EDM 2 / Start 2)
1.Y2 (EDM 3 / Start 3)
2.Y2 (EDM 4 / Start 4)
1.13
1.14
2.13
2.14
Eingänge
(Inputs)
Freigabe
(Release)
0 V
4.14
24 V
3.14
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
+
-
+
-
+
-
2.13
+
24 V
2.Y1
0 V
+
1.13
2.Y2
1.Y2
2.14
+
4.14
+
1.14
1.Y1
3.14
+AS I 1–
+AS I 2–
AS I 1 +PWR– (max. 4A)
AS I 2 +PWR– (max. 4A)
output switching elements
EDM/Start inputs
EDM/Start inputs
output switching elements