EUCHNER AS-i Safety Monitor for 2 AS-i circuits User Manual
Page 71

AS-i Safety Monitor for 2 AS-i circuits
Operation in advanced display mode
Subject to reasonable modifications due to technical advances
Id.-No.: 103336
Issue date - 24.10.2008
EUCHNER GmbH + Co. KG
71
Kohlhammerstraße 16 • D-70771 Leinfelden-Echterdingen
Tel. +49/711/75 97-0 • Fax. +49/711/753316
This menu displays the diagnosis at the time the Safety Monitor was deactivated.
For additional information, please refer to the <ASIMON> documentation.
DIAGNOSE
CH 1
OK
LAST DIAGNOSIS
CH1 COMPLETE
DIAG INDEX
INT SAFETY MON
LAST DIAG CH1
CH1.: OFF
A COLOR
32 RET
33 GREY
34 YEL FL
....
HELP:
A DEVICE ADDR.
+ CHANGED
Complete:
The complete diagnostic is read out.
DIAG INDEX:
The diagnostic is shown as it was configured under the
"device_index_assignment" in ASIMON
Information!
If the diagnosis is read using DIAG INDEX, the device count begins at 0, otherwise at
32!