Byte
No.
Description
ASCII
C O N T E N T S
HEX
Decimal
0
Number of telegram Bytes
8 ... 23
1
2
Command
identification
R
L
52
4C
82
76
3
Read/write head address *)
01
01
4
5
Start address of
user data
00
0 ... Fh
00
0 ... 15
6
Number of Bytes of
user data
1 ... 10h
1 ... 16
7 ... 22 User data
ASCII or HEX resp. BCD (code-transparent)
Figure 8: Response telegram "Read data carrier" (telegram core)
Byte
No.
Description
ASCII
C O N T E N T S
HEX
Decimal
0
Number of telegram Bytes
7
1
2
Command
identification
R
F
52
46
82
70
3
Read/write head address *)
01
01
4
5
Padding data
00
00
00
00
6
Error number
Error No.
Error number f = 02: Data carrier not in active area
Figure 9: Response telegram "Read data carrier" (telegram core)
*)
For downward compatibility with the CIS2 identification system.
The content of the header address must always by 1 in the case of CIS3.