Command overview, Error messages – EUCHNER CIS3(A) User Manual
Page 13

EUCHNER
Identsystem
CIS3
071652-01-8/99
Subject to technical modifications
page 13 / 23
5.3. Command overview:
Description
Command telegram
Response telegram
Program data
(Num. Tele-Bytes)
TP
(Read/write head address *)
(Start address)
(Number of Bytes user data)
(User data.....)
(Num. Tele-Bytes)
RF
(read/write head address *)
(Error No.)
Read data carrier
in active area
(Num. Tele-Bytes)
TL
(Read/write head address *)
(Start address)
(Number of Bytes user data)
(Num. Tele-Bytes)
RL
(read/write head address *)
(Start address)
(Number of Bytes user data
(User data)
or
(Num. Tele-Bytes)
RF
(read/write head address *)
(Error No.)
*)
For downward compatibility with the CIS2 identification system.
The content of the header address must always by 1 in the case of CIS3.
6. Error messages
02h
Data carrier not in active area
03h
Read operation aborted
04h
Error while programming or while check-reading the data carrier
05h
Write operation aborted, remove data carrier from active area
16h
Data length greater than 16 Bytes