6.1.1 Ethernet configuration

The Electronic-Key adapter can be configured for the following operating modes with DIP switch S3 (see section
4.4.3):

f With a fixed IP address

f As a DHCP client with dynamic IP address

f As a DHCP client for a SINUMERIK control system with dynamic IP address based on a fixed station name

(see section 4.4.2)

In addition, the following service functions can be set with DIP switch S3:

f Reset to default IP address (see sections 4.4.3 and 6.1.1.1)

f Permit or prohibit configuration via a web browser (see sections 4.4.3 and 7.2)

The individual functions are described below in detail.

6.1.1.1 Fixed IP address and default IP address

Fixed IP address

In this operating mode, communication with the Electronic-Key adapter is via a fixed IP address. In the default
setting on delivery, the factory-set default IP address is 192.168.1.1 and the subnet mask is 255.255.255.0.

Information!

f This operating mode is not suitable for operation in conjunction with a DHCP server.

f The DIP switches S3.3 and S3.4 always remain OFF in this operating mode (see DIP switch

settings in section 4.4.3).

f On powering up the Electronic-Key adapter, the fixed IP address last set is always active after the

application of the power supply in this operating mode.

You can assign an individual fixed IP address via the web interface of the Electronic-Key adapter (see section
7.2). To do this, access via a web browser must be enabled (see DIP switch settings in section 4.4.3).

Default IP address

Every Electronic-Key adapter has the factory-set default IP address 192.168.1.1 and the subnet mask
255.255.255.0.

Information!

If you have forgotten your self-defined IP address, you can reset the Electronic-Key adapter to the
default address again. The self-defined address is then overwritten by the default address.

For this purpose proceed as follows. The Electronic-Key adapter can be connected to the network or
disconnected from the network during this routine.

1. Disconnect

Electronic-Key

adapter from the power supply.

2. Set DIP switch S3.3 (see DIP switch settings in section 4.4.3) to ON.

3. Apply power supply. Wait until the Electronic-Key adapter has fully powered up. During power up the LED is

illuminated red constantly. The completion of the process is indicated by a change in this state after approx.
20 seconds. The Electronic-Key adapter is now reset to the default IP address 192.168.1.1 and the subnet
mask 255.255.255.0.

4. Disconnect Electronic-Key adapter from the power supply. Set DIP switch S3.3 to OFF (see DIP switch

settings in section 4.4.3).


After the application of the power supply, the Electronic-Key adapter now powers up again with the default IP
address. A new, fixed, self-defined IP address can now be set again using the web interface (see above).