Limited warranty – Flint & Walling Evaporative Cooling Pumps User Manual

Page 2

Advertising
background image

2

© 2011. All rights reserved.

This product is warranted for one year from the date of purchase or two years
from the date of manufacture, whichever occurs first. Subject to the conditions
hereinafter set forth, the manufacturer will repair or replace to the original
consumer, any portion of the product which proves defective due to defective
materials or workmanship. To obtain warranty service, contact the dealer from
whom the product was purchased. The manufacturer retains the sole right and
option to determine whether to repair or replace defective equipment, parts or
components. Damage due to conditions beyond the control of the manufacturer is
not covered by this warranty.

THIS WARRANTY WILL NOT APPLY: (a) To defects or malfunctions resulting from
failure to properly install, operate or maintain the unit in accordance with printed
instructions provided; (b) to failures resulting from abuse, accident or negligence or
use of inappropriate chemicals or additives in the water; (c) to normal maintenance
services and the parts used in connection with such service; (d) to units which are
not installed in accordance with normal applicable local codes, ordinances and
good trade practices; and (e) the unit is used for purposes other than for what it
was designed and manufactured.

RETURN OF WARRANTED COMPONENTS: Any item to be repaired or replaced
under this warranty must be returned to the manufacturer at Kendallville, Indiana or

LIMITED WARRANTY

such other place as the manufacturer may designate, freight prepaid.

THE WARRANTY PROVIDED HEREIN IS IN LIEU OF ALL OTHER EXPRESS
WARRANTIES, AND MAY NOT BE EXTENDED OR MODIFIED BY ANYONE.
ANY IMPLIED WARRANTIES SHALL BE LIMITED TO THE PERIOD OF
THE LIMITED WARRANTY AND THEREAFTER ALL SUCH IMPLIED
WARRANTIES ARE DISCLAIMED AND EXCLUDED. THE MANUFACTURER
SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE FOR INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES, SUCH AS, BUT NOT LIMITED
TO DAMAGE TO, OR LOSS OF, OTHER PROPERTY OR EQUIPMENT,
LOSS OF PROFITS, INCONVENIENCE , OR OTHER INCIDENTAL OR
CONSEQUENTIAL DAMAGES OF ANY TYPE OR NATURE. THE LIABILITY OF
THE MANUFACTURER SHALL NOT EXCEED THE PRICE OF THE PRODUCT
UPON WHICH SUCH LIABILITY IS BASED.

This warranty gives you specific legal rights, and you may have other rights which
vary from state to state. Some states do not allow limitations on duration of implied
warranties or exclusion of incidental or consequential damages, so the above
limitations may not apply to you.

WARRANTY VALID IN CANADA AND MEXICO.

CONDITION

COMMON

CAUSES

A. Pump will not start or run.

Check fuse, low voltage, over load open, open or incorrect wiring,

open switch, impeller or seal bound mechanically, defective capaci-

tor or relay when used, motor or wiring shorted.

B. Motor overheats and trips overload or blows fuse.

Incorrect voltage, negative head (discharge open lower than

normal) impeller or seal bound mechanically, defective capacitor or

relay, motor shorted.

C. Pump starts and stops too often.

Check valve stuck or none installed in long distance line, over load

open.

D. Pump operates but delivers little or no water.

Check strainer housing, discharge pipe, or if check valve is used

vent hole must be clear. Discharge head exceeds pump capacity.

Low or incorrect voltage. Incorrect motor rotation. Capacitor defec-

tive. Incoming water containing air or causing air to enter pumping

chamber.

E. Drop in head and/or capacity after a period of use.

Increased pipe friction, clogged line or check valve. Abrasive mate-

rial and adverse chemicals could possibly deteriorate impeller and

pump housing. Check line. Remove base and inspect.

If the above checklist does not uncover the problem, consult the factory - Do not attempt to

service or otherwise disassemble pump.

SERVICE CHECKLIST

ELECTRICAL PRECAUTIONS- Before servicing a pump, always shut off the main power breaker and then unplug the pump

- making sure you are wearing insulated protective sole shoes and not standing in water. Under flooded conditions, contact

your local electric company or a qualified licensed electrician for disconnecting electrical service prior to pump removal.

Advertising