PRODUCT INSTRUCTIONS

www.rosco.com

OPERATING INSTRUCTIONS

Before using the real flame GAMTorch™, check the

safety release latch to ensure it’s working properly.

TO CHECK SAFETY RELEASE LATCH [4]:

Pull down Flame Containment Sleeve [4] and hold

Safety Release Latch [5] over Latch Button [7] on

handle. Fire Chamber [3] should remain in the ex-

posed position as long as safety release latch is

held. Release Safety Release Latch [5] and observe

that the Flame Containment Sleeve [4] completely

shrouds the Fire Chamber [3] and the Containment

Lid [1] snaps over the top of the Fire Chamber [3].

This action is instant, taking less than one second.

IF SAFETY RELEASE LATCH IS MALFUNCTION-

ING, DO NOT USE THE GAMTORCH! CONTACT

GAMPRODUCTS, INC. FOR SERVICE.

Only after checking that the Safety Release Latch [5]

is functioning properly, proceed to load GAMFuel™

pellets into the Fire Chamber [3]. Load one to four

pellets, depending on size of flame and duration

desired. Do not load more pellets than needed. Be

sure to hold down Safety Release Latch [5] while

loading Fire Chamber [3]. After loading Fire Cham-

ber [3], secure GAMFuel™ pellets with Retaining

Spring [2]. Refer to detail drawing on right. Con-

ceal the chamber by releasing the Safety Release

Latch [5]. The GAMTorch™ is now loaded and

ready for use.

Retaining Spring [2]

flat against the top

of Fire Chamber

Containment Lid [1] (open)

Flame Containment

Sleeve [4]

Safety Release

Latch [5]

Handle [6]

Latch Button [7]

Retaining Spring [2]

(insert into Fire Chamber)

Hilt Cap

Containment Lid [1] (closed)

Fire

Chamber [3]

WARNING!:

To insure that the GAMFuel™

pellets stay in place, insert retain-

ing spring [2] so that it is flush

with top of fire chamber.

Slide Containment Sleeve

down to expose fire chamber

YOU ARE HANDLING REAL FIRE WHEN YOU USE THE
GAMTORCH™! USE CAUTION AT ALL TIMES!

Be aware of automatic fire sprinkler heads that may

be in the area. Always be careful not to get flame

too close to costumes, scenery, people’s hair or oth-

er flammable objects. Use the GAMTorch™ only in

approved venues where all safety precautions con-

cerning fire are observed, and permits have been

obtained (if applicable). Use only where there is

proper ventilation and exhaust. The GAMTorch™ is

intended for professional use only.

When you are ready to use the GAMTorch™, slide the

Flame Containment Sleeve [4] down and grip the Safe-

ty Release Latch [5] firmly. Be sure to hold the Safety

Release Latch [5] over Latch Button [7]. Use a lighter or

match to ignite the GAMFuel™ in the Fire Chamber [3].

Long fireplace matches or ‘extended’ matches are ideal

for this purpose. Light the GAMTorch™ approximately 30

seconds before a full flame is desired.

GAMFuel™ pellets will burn for approximately 15

minutes, depending on the ventilation conditions

and flame height can be as much as 16 in (40 cm).

Exercise extreme caution when in use! Dispose of

spent fuel pellets carefully, making sure they are fully

extinguished. Dump fuel pellets in pan with a small

amount of water before disposal. Store GAMFuel™

pellets at temperatures below 155o F (68o C).