HDA.SAE – Analog signal ISO to HDA 5500

The HDA.ISO signal consists of 6 measured values (START / ISO 6 / ISO 6 / ISO 14
/ ISO 21 / Status) which are output sequentially. Synchronization with the
downstream control unit is a prerequisite.

The signal output is as follows:

Time

Measurement

category

Signal duration

in s

Current/Voltage

Start signal 0

--

2

20 mA / 10 V

Pause

2

4 mA / 2 V

Signal 1

ISO 4

2

Current/Voltage for signal

Pause

2

4 mA / 2 V

Signal 2

ISO 6

2

Current/Voltage for signal

Pause

2

4 mA / 2 V

Signal 3

ISO 14

2

Current/Voltage for signal

Pause

2

4 mA / 2 V

Signal 4

ISO 21

2

Current/Voltage for signal

Pause

2

4 mA / 2 V

Signal 5

Status

2

Current/Voltage for signal

Pause

30

4 mA / 2 V