HYDAC ETS 1700 User Manual
Page 7

8. Basic
settings
In order to adapt the unit to the particular application, the function of the ETS 1700 can be
altered via several basic settings. These are combined in one menu.
8.1 Altering the basic settings
2 s
2 s
+
_
+
display
press ON and
OFF keys of
switching point 1
simultaneously
ON
OFF
m
o
d
e
SP1
*
+
select menu point using single
ON
OFF
m
o
d
e
SP1
+
alter setting,
key. (ON for next,
OFF for previous menu point)
then select next
menu point
To close the basic setting menu:
Call up the menu point END, set to YES, the ETS 1700 returns to the normal display mode after
2s.
Or:
Press ON and OFF keys of switching point 1 simultaneously, END is displayed, the ETS 1700
returns to normal display mode after 2s.
Notes:
• If ”HIDE” is displayed instead of ”MENU”, the menu can only be called up if the keys are held
down when the supply voltage is switched on (see Point 8.2 ”Summary of basic settings,
Hidden basic setting menu”)
• When changing the display range, the switching point and hysteresis or switch-back point
settings are converted automatically. This can cause minor rounding errors.
• If after 50 seconds no keys have been pressed, the menu automatically closes down. Any
changes which may have been made will not be saved.