Setup - mounting to your router table – INCRA LS Positioner User Manual

Page 5

Advertising
background image

INCRA LS Positioner Owner’s Manual

5

Fence Mounting Bracket

This heavy steel bracket provides a quick and

easy means to attach the Pro II Fence, the Wonder

Fence, or the TS table saw fence.

Micro Adjust Knob

With the carriage clamp in the micro adjust

position, use this knob to fine-tune the location

of your fence in

1

/

1000

” increments (1/40mm for

metric version.) Ball bearing engaged detents on

the knob provide an audible click for each

1

/

1000

(1/20mm) of adjustment. The pointer and easy

to read scale give a clear readout of your fence

movement. Turning the knob clockwise moves the

fence closer to the cutter. Turn it counterclockwise

and the fence moves away from the cutter. Each

full turn of the knob moves the fence

1

/

32

” or 1mm

for the metric version.

Micro Adjust Scale Dial

This laser engraved dial provides a clear reference

for micro adjustments. Each mark on the dial

represents

1

/

1000

” (1/40mm for metric version.)

After micro adjusting, the dial can be re-zeroed to

the pointer for future adjustments.

FIg. 1

SetuP - MOuntInG tO YOur rOuter tABle

Note: If you are setting up a table saw-based LS,

read the Getting Acquainted and Operations section

of this manual, then follow the instructions in the

TS-LS owner’s manual.

Drill Mounting Holes

Unlock the carriage clamp and carefully remove

the carriage from the LS base. For maximum access
to fence system range, locate the leading edge of
the LS base the following distance from the center
of your router collet: 19¾” for the 17” (430mm)
range model or 27¾” for the 25” range model, Fig. 2.
Center the LS Base across the width of your table. If
you have a router table top that is not long enough to
handle the full range of your

LS Positioner, see the

Tip on page 6 for an easy way to extend your table
dimensions.

Note: While it is permissible to allow some of the

LS Base to overhang the table, a minimum of 4” of

the LS Base must be overlapped onto the table for

secure mounting.

1

FIg. 2

Locate leading edge of LS Base on your router table

19¾” (17” m

odel)

27¾” (25” m

odel)

Leading Edge

LS Base

Advertising