ON

Starts instrument.

When the detector is started the ten LEDs

light up and subsequently counting down

during the warm up sequence. The detec-

tor is ready to use when the countdown is

completed.

OFF

Turns instrument off.

SENSITIVITY

▲ and ▼.

The sensitivity of the detector can be set

to 10 different levels. The highest levels

are extremely sensitive. Conclusions to

excavate for the repair of a leak should not

normally be made without reconfirming

on sensitivity 5 or lower. Use the higher

sensitivities for faster identification of

suspect areas. Confirm the leak position

by measuring more carefully at a lower

sensitivity.

Wait until the concentration has increased

or make a few holes for higher signals. Ex-

cavate only on signals that you can repeat

over and over again.

The sensitivity is changed by pressing the

SENSITIVITY up or down key. Pressing

the key momentarily once will increase or

decrease sensitivity one level and the cor-

responding LED will light up shortly. The

sensitivity will increase/decrease to max or

min if the key is held down for longer.

NOTE!

The sensitivity can not be changed

when the instrument is in MAX mode.

Switch to SEARCH mode for changing

sensitivity.

VOLUME

▲ and ▼ set the audio volume.

The volume setting changes stepwise to

max/min if key is held down.

Volume setting is stored after 1 minute.

BATT CHECK

shows charge status.

10 LEDs indicates fully charged battery

(approximately 15 h of operation).

LED 1 – 5 indicates approximately 1 hour

of operation / LED.

ZERO

resets signal to zero.

SEARCH

sets instrument in SEARCH

mode.

Auto Power Off

The instrument will switch off after 30

minutes if no key is pressed.

Battery protection feature

The instrument will automatically switch

off if the battery voltage falls below 5.0

V. This protects the battery from harmful

deep discharge.