Installation – Johnson Systems JS-ICON 624 ARCH Dimmer Rack User Manual

Page 5

Advertising
background image

www.johnsonsystems.com

4

www.johnsonsystems.com

5

12”

(305 mm)

13”

(330 mm)

Installation

Mounting
The JS-ICON

624 ARCH can be mounted to any wall surface capable of

supporting its weight (35 lbs (15.9 kg) for each rack). Four 1/4” (6mm) screws

or bolts are required to fasten the rack safely to the wall (see the drawing

below for mounting locations and dimensions). To access the mounting

locations, remove the contractor wiring access panel, remove the breaker

panel, and open the hinged service bay door. For further access to the

mounting locations, the hinged service bay door, and left side panel, can be

easily removed (see instructions on page 6 for more details).
Multiple racks may be mounted horizontally (side by side) with no clearance

between them, while vertical mounting requires a minimum of 18” (432mm) of

clearance between the racks to allow for adequate separation for ventilation.

A minimum of 12” (305mm) of clearance is required for the racks cool air

intake and hot air exhaust (see diagram on page 6 for more details).

WARNING: Mount the racks only as indicated above. Failure to comply may
cause thermal overheating.

Power Supply and Load wiring / conduit entry

Low-Voltage wiring / conduit entry

Left Side Panel mounting screws

Hinged Service

Bay Door

Contractor Wiring

Access Panel

Breaker Panel

Top View Hot Air Exhaust

Bottom View Cool Air Intake

Advertising