PTY A

Press EXECUTE to toggle into Priority A (PTY A) mode.

PTY B

Press EXECUTE to toggle into Priority B (PTY B) mode.

MERGE

Press EXECUTE to toggle into Merge (MERGE) mode.

DMX A+B

Press EXECUTE to toggle into Dual Universe DMX (DMX A+B) mode.

2 ROOM

Press EXECUTE to toggle into Two Room (2 ROOM) mode.

Press ESCAPE or RESET to exit the menu.

Any change in the configuration is automatically saved.

10. 2 RM SET

Set the two room assignment for each of the dimmer outputs.

This menu is used to assign each of the 12 or 24 dimmer outputs to room “A” or

room “B”. Dimmer outputs assigned to room “A” are controlled via the DMX-A input.

Dimmer outputs assigned to room “B” are controlled via the DMX-B input. This

creates separation within the dimmer rack and makes a single dimmer rack function

as though it is two independent dimmer racks. When used in conjunction with the DC

PATCH menu, the dimmer rack can be configured for sequential DMX control of two

rooms, even if the dimmer room assignments are not sequential.

DMX MODE must be set for 2 ROOM operation for this menu to function.

Press EXECUTE to enter the menu and activate 2 RM SET mode.

DIM 01 A

Displays the dimmer (DIM) output (01) and the room assignment (A).

DIM 24 A

Press MENU ( ) to select a different dimmer output from 01 to 12 or 24.

DIM 24 B

Press EXECUTE to toggle the room assignment from A to B.

Press ESCAPE or RESET to exit the menu.

Any change in the configuration is automatically saved.

NOTE: Scene mode (SCENESET) will only activate/control dimmers assigned to

room “A”.

11. SH TIME

Set the DMX status hold time from 0 to 99 minutes or infinite.

When DMX is disconnected the system will hold the status of the last received DMX

levels for the selected amount of time. When activated, the LCD display shows a

countdown of the status hold time or infinite hold.

Press EXECUTE to enter the menu.

HTIME 00

Displays the current DMX status hold time (HTIME) setting.

HTIME 99

Press MENU ( ) to set the desired hold time from 00 to 99 minutes.

HTIME XX

Press MENU ( ) to set the desired hold time to infinite (XX).

HTIME 00

Press both MENU ( ) switches to toggle back to status hold time of 00.

Press ESCAPE to exit the menu and save the desired DMX status hold time.

Press RESET to exit the menu without saving.

The menu will automatically timeout after 2 minutes of inactivity and save.

12. DC PATCH

Configure the dimmer to channel patch for the dimmer pack.

Each of the 12 or 24 dimmer (PWM) outputs can be assigned and patched to any of

the 12 or 24 control channels. Multiple dimmer outputs may be patched to a single

control channel. The dimmer to channel patch is used by other menu features to

provide transparent control of the dimmer output circuits. DPC-12 and DPC-24 control

modules are typically patched for 1 to 1 operation but may be altered for custom

applications.

Press EXECUTE to enter the menu.

D01<C01

Displays the dimmer (D) output (01) and its current control channel (C) patch (01).

D24<C24

Press MENU ( ) to select the desired dimmer output from 01 to 12 or 24.

D24 C24<

Press EXECUTE to toggle the pointer (<) to select the control channel to patch.

D24 C01<

Press MENU ( ) to select the desired control channel from 01 to 12 or 24.