Dpc-24/12 – Johnson Systems DPC-24-3000 Series Digital Pack Controller User Manual

Page 4

Advertising
background image

www.johnsonsystems.com

4

EEPROM

MEMORY

MODULE

EEPROM

BACKUP &

FIRMWARE

UPDATE

(EDGE3) (EDGE2)

MOVE JUMPERS (x3)

TO LEFT-HAND SIDE POSITION

TO ENABLE INTERNAL DMX-B INPUT

MADE IN CANADA

WWW.JOHNSONSYSTEMS.COM

CD80 DIGITAL PACK CONTROLLER

REV.1 1132

SERIAL NUMBER

3000 SERIES

DPC-24/12

FAN FUSE

REPLACE WITH

2A 250V

FAST-ACTING

GMA TYPE

FUSE ONLY!

CAUTION: AC LINE VOLTAGE!

EDGE2, 16-Pin
Edge Connector

PIN FUNCTION

13 DMX-B Input Data+

15 DMX-B Input Data-

16 DMX-B Input Shield / Common

EDGE3, 20-Pin
Edge Connector

PIN FUNCTION

1

DMX-B Input Shield / Common

2

DMX-B Input Data+

4

DMX-B Input Data-

• If the DMX input is connected internally, on a terminal block mounted

inside the CD80 dimmer pack, jumpers will need to be moved on the

DPC-24/12 circuit board to enable the DMX-B input. To enable the internal

DMX through the EDGE2 connector on the DPC-24/12 circuit board, move

the three (3) jumpers on JP2 to the left-hand side position. To enable the

internal DMX through the EDGE3 connector on the DPC-24/12 circuit

board, move the three (3) jumpers on JP3 to the left-hand side position.

• Line up the DPC-12 or DPC-24 control module with the guide rails on each

end of the control module slot.

• Carefully slide the DPC-12 or DPC-24 control module in until the

connectors on the DPC-24/12 circuit board touch the rear connectors

inside the CD80 dimmer pack.

• Line up the two (2) thumbscrews on the DPC-12 or DPC-24 with the

mounting holes on the CD80 dimmer pack.

• Firmly push the DPC-12 or DPC-24 in on both ends until the control

module is fully seated.

NOTE: If it feels like the control module isn’t fully seated or doesn’t slide in

easily, it may be necessary to re-align the rear connectors inside

the CD80 dimmer pack to their upper most position, due to the

inconsistencies in the assembly of the CD80 dimmer pack. This can

be accomplished by loosening the two (2) mounting screws on each

end of the rear connectors by half a turn, sliding the connectors up as

much as possible and then re-tightening the mounting screws.

• Tighten the two (2) thumbscrews to secure the DPC-12 or DPC-24 in the

CD80 dimmer pack.

Turn on and test the new DPC-12 or DPC-24 retrofit control
module

• Connect (turn on) the power supply to the to the CD80 dimmer pack.

• Verify the operation of the system status LED indicators, LCD display and

programming switches.

• Refer to the programming section of this manual for system configuration.

• Test the system thoroughly to ensure everything is functioning properly.

• Verify all of the dimmer control outputs have the correct phase referencing.

If a dimmer control output is patched to the incorrect phase reference, the

dimmer will not dim correctly and will go to full output at around 1% DMX

input. The factory configuration for DPC-12 and DPC-24 control modules

is for standard three-phase applications, with the dimmer phase reference

patch set at AAAABBBBCCCC… For standard single-phase applications,

set the default (DEFAULT) menu for single-phase (1ØPATCH) operation,

with the dimmer phase reference patch set at AAAAAAAACCCCCCCC…

The phase patch (Ø-PATCH) menu must be used to configure non-

standard applications.

• Verify the fan inside the CD80 dimmer pack is operating properly. The fan

should turn on with between 6-7% DMX (or other) control – when DMX (or

other) control drops below 6-7%, there is a 5 minute timeout on the fan to

ensure the dimmers have been cooled sufficiently. If required, replacement

fans are available (Johnson System Inc., Part Number: CF-CD80P).