RWB 6104 BAFG R02

Table 1 – Burner Specifi cations

Capacity
(Note 1)

‘F’ Head (AF & AFG)
Firing rate range: ..............0.40 – 3.00 GPH
Input: ....................... 56,000 – 420,000 Btu

‘L1’ Head (AFG Only)
Firing rate range: ..................0.40 - 1.10 GPH
Input: ..................... 56,000 – 154,000 Btu/h
‘L2’ Head (AFG Only)
Firing rate range: .................0.50 - 1.00 GPH
Input: ...................... 70,000 – 140,000 Btu/h
‘V1’ Head (AFG Only)
Firing rate range: .................0.75 - 2.75 GPH
Input: .................... 105,000 – 385,000 Btu/h

Certifi cations/

Approvals

UL certifi ed to comply with ANSI/UL296 &

tested to CSA B140.0

Fuels

U. S: No.1 or No.2 heating oil only
(ASTM D396)
Canada: No. 1 stove oil or No. 2 furnace oil
only

Electrical

Power supply: ............... 120 volts AC, 60 Hz,
single phase
Operating load: .......................5.8 Amps max
Motor: ............ 1/7 hp, 3450 rpm, NEMA 48M
frame PSC rotation CCW
when facing shaft end
Ignition: ... Continuous duty solid-state igniter

Fuel pump

Outlet pressure: ..................................Note 2

Air tube

ATC code: ...................................See Table 2

Dimensions
(with cover)

Height (maximum) ....................... 12.5 inches
Width (maximum) .......................... 15 inches
Depth ......................................... 9.25 inches
Air tube diameter ....................... 4.00 inches

Note 1: Approval agency listed rating for these burners is 0.40 to

3.00 gph. However, the fi ring rate range is limited by the
specifi c air tube combination being used. Refer to Table 2.

Note 2. See appliance manufacturer’s burner specifi cations for rec-

ommended pump discharge pressure.

General Specifi cations

Table 2 – Air Tube Combination (ATC) codes

Firing

Rate

(gph)

Head

Static

plate

size

Ven-

turi

ATC Codes for usable air tube lengths

(‘A’ in inches; See Figure 3.)

(min-

max)

(inch-

es)

4-1/2

5

5-3/8

6-5/8

7

7-1/4

9

10-1/2

13

16

0.50-0.75

F0

3-3/8U

None

AF44XR

-

AF53XR

AF65XR

-

AF72XR

AF90XR

AF104XR

AF130XR

A160XR

0.75-1.25

F3

2-3/4U

None

AF44XN

-

AF53XN

AF65XN

-

AF72XN

AF90XN

AF104XN

AF130XN

AF160XN

0.85-1.35

F4

2-3/4U

None

AF44WH

-

AF53WH

AF65WH

-

AF72WH

AF90WH

AF104WH

AF130WH

AF160WH

0.85-1.65

F6

2-3/4U

None

AF44YB

-

AF53YB

AF65YB

-

AF72YB

AF90YB

AF104YB

AF130YB

AF160YB

1.10-2.00

F12

2-3/4U

None

AF44XO

-

AF53XO

AF65XO

-

AF72XO

AF90XO

AF104XO

AF130XO

AF160XO

1.65-2.50

F22

2-3/4U

None

AF44XP

-

AF53XP

AF56XP

-

AF72XP

AF90XP

AF104XP

AF130XP

AF160XP

2.50-3.00

F31

None

None

AF44XS

-

AF53XS

AF65XS

-

AF72XS

AF90XS

AF104XS

AF130XS

AF160XS

0.50-1.10

L1

3-3/8U

8hole

-

AFG50MB

-

-

AFG70MB

-

AFG90MB

-

-

-

0.50-1.00

L2

2-3/4U

8hole

AFG50MP

-

-

AFG70MP

-

AFG90MP

-

-

-

0.75-2.75

V1

2-3/4U

8hole

-

AFG50MD

-

-

AFG70MD

-

AFG90MD

-

-

-

0.40-0.75

F0

3-1/2U

None

AF44WG

-

AF53WG

AF65WG

-

AF72WG

AF90WG

AF104WG

AF130WG

A160WG

Please read and understand the manual supplied with

this equipment. This equipment must be installed, adjust-
ed and put into operation only by a qualifi ed individual or
service agency that is:

Licensed or certifi ed to install and provide techni-
cal service to oil heating systems.
Experienced with all applicable codes, standards
and ordinances.
Responsible for the correct installation and com-
mission of this equipment.
Skilled in the adjustment of oil burners using com-
bustion test instruments.

The installation must strictly comply with all applicable

codes, authorities having jurisdiction and the latest revi-
sion of the National Fire Protection Association Standard
for the installation of Oil-burning Equipment, NFPA 31 (or
CSA B139 and B140 in Canada).

Regulation by these authorities take precedence over the

general instructions provided in this installation manual.

y

y

y

y

Incorrect installation, adjustment,

and use of this burner could result
in severe personal injury, death, or
substantial property damage from

WARNING

!

Professional Service

Required

fi re, carbon monoxide poisoning, soot or explo-
sion.