Mechanical installation – Lenze 8400 User Manual

Page 150

Advertising
background image

Mechanical installation

Standard devices in a power range of 30 ... 45 kW

Mounting in ”cold plate” technique

5

150

EDS84ASC552 EN 9.1

StateLine, HighLine

8400GG108a

Fig. 5-46

Dimensions for mounting

d

1

d

2

d

3

c

c

1

c

2

c

3

i

j

11

j

21

[kW]

[mm]

[kg]

E84AVxxC3034xXx

30

8

12

500

40

20

20

210

0

> 95 > 120 16.7

E84AVxxC3734xXx

37

E84AVxxC4534xXx

45

E84AVxxC3034xBx

30

8

12

500

40

20

20

210

0

> 95 > 120 16.8

E84AVxxC3734xBx

37

E84AVxxC4534xBx

45

Advertising