Warning, Ramp installation – Braun RA500 User Manual

Page 31

Advertising
background image

Positive (+) battery

lead wire must be

protected by

installer-provided 25

ampere fuse or

circuit breaker.

Failure to do so may

result in serious

bodily injury and/or

property damage.

WARNING

The 2 pin power harness connec-

tor and the 14-pin data harness

connector are supplied with the

ramp.

Note: Connectors are supplied

only, harnesses are supplied by

ramp installer. The ramp installer

is responsible for vehicle connec-

tions.

The ramp installer provides an

appropriate momentary contact

control switch.

Terminate the power supply,

ground and ramp data signals as

specified in the legends below.

The Positive (+) “battery” lead

wire must be protected by an

in-line 25 ampere fuse or circuit

breaker (installer provided).

Electrical Connections

RAMP INSTALLATION

Output

1

Indicator - Move Out - Normally Open (N.O.)

14 to 18 Gauge

Output

2

Indicator - Alarm - Normally Open (N.O.)

14 to 18 Gauge

Input

3

Switch - Ramp Deploy

14 to 18 Gauge

Input

4

Switch - One Touch

14 to 18 Gauge

Input

5

Indicator - Power Common Fused

14 to 18 Gauge

Output

6

Indicator - Manual Release - Normally Open (N.O.)

14 to 18 Gauge

Input

7

Ramp Enable

14 to 18 Gauge

Output

8

Switch - Common

14 to 18 Gauge

Output

9

Indicator - Full In - Normally Open (N.O.)

14 to 18 Gauge

Input

10

Switch - Ramp Stow

14 to 18 Gauge

Input

11

Switch - Park Brake (LOW) to Operate

14 to 18 Gauge

Output

12

Indicator - Move In - Normally Open (N.O.)

14 to 18 Gauge

Output

13

Indicator - Full Out - Normally Open (N.O.)

14 to 18 Gauge

Input

14

Switch - Park Brake (HIGH) to Operate

14 to 18 Gauge

Function

Pin No.

Description Wire Size

Input

1

Battery - 24 Volt with 25 Amp. Protection Device

10 Gauge

Input

2

Ground - Battery

10 Gauge

Wire Maximum Length: 10 Meters

Function

Pin No.

Description Wire Size

Notes: Either the One touch

switch or both the Deploy and

Stow switch connections should

be utilized but not both.

The Park Brake switch (either

high or low) and Ramp Enable

are required for ramp to operate.

Ramp Enable requires + Vehicle

power to operate.

See metric to US wire size con-

version chart on page 43.

Power Harness with Molex 42816-0212 Connector (installer provided)

Data Harness with AMP 206044-1 Connector (installer provided)

Page 29