Warning, Systems descriptions – Braun RA500 User Manual

Page 38

Advertising
background image

Page 36

Electrical

Improper microswitch

adjustment may

result in serious

bodily injury and/or

property damage.

WARNING

Microswitches: Three micro-

switches (limit switches) are in-

corporated in the RA500 electrical

system (IN-Limit, OUT-Limit and

Manual Release signal). Details

and illustrations of the micro-

switches are provided. Adjust

microswitch (es) as detailed.

Microswitch Sequence

Stowed Position: When the

ramp is in the stowed posi-

tion, the IN-Limit microswitch is

activated (common and normally

open terminals have continuity).

In contrast, the OUT-LImit micro-

switch is deactivated.

Deploy Sequence: When the

ramp is in the stowed position,

the OUT-Limit microswitch is de-

activated, and thus allows current

to pass from the vehicle’s Deploy

switch circuit and energize the

ramp’s Bidirectional motor in the

deploy direction (motor drives

chains to deploy ramp).

Deployed Position: When the

ramp is in the deployed position,

the OUT-Limit microswitch is ac-

tivated. In contrast, the IN-Limit

microswitch is deactivated.

Stow Sequence: When the ramp

is in the deployed position, the IN-

Limit microswitch is deactivated ,

allowing current to pass from the

vehicle’s Stow switch circuit and

energize the ramp’s Bidirectional

motor in the stow direction (motor

drives chains to stow ramp).

Manual Release State: When

the ramp’s manual release is

engaged the manual release

microswitch signals the control-

ler that the manual release state

of the ramp has been engaged.

This signals the controller to dis-

able the power functions of the

RA500.

SYSTEMS DESCRIPTIONS

OUT-Limit Microswitch

The OUT-Limit microswitch is located in the out-

board mounting position of the platform carrier plate.

To adjust:

. Power or manually move the ramp to the full out

position.

2. With the ramp in the deployed position loosen

the OUT-Limit microswitch mounting screws.

3. Slide the switch body outward until resistance is

felt from the switch being fully depressed.

4. Tighten the mounting screws in this position.

Note: Under normal circum-

stances the RA500 microswitches

should not need adjustment. If

adjustment or replacement is

required, follow the procedures

provide on the next page.

Figure L

Ramp in Full-Out Position

(As viewed from under the carrier plate)

OUT-Limit

Microswitch

Advertising