Lenze I/O system 1000 User Manual
Page 20

4
Mapping the real station structure in the »PLC Designer«
4.3
Configuring I/O modules on the EtherCAT bus coupler module
20
Lenze · I/O system 1000 · commissioning guidelines for the PLC Designer · DMS 1.2 EN · 11/2012 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3. Click Add device to add the selected device to the L-force Controller.
• The Add device dialog box remains open.
Adding the EtherCAT bus coupler module (slave) to the EtherCAT master
4. Select the "EtherCAT_Master" device in the device view:
5. Now select the "EPM-S130" device (EtherCAT bus coupler module) in the still opened Add
device dialog box.
6. Click Add device to add the selected device to the EtherCAT master.
• The Add device dialog box remains open.
Adding I/O compound modules to the EtherCAT bus coupler module
7. Select the "EPM_S130" device in the device view:
8. Select the physically first I/O compound module in the still opened Add device dialog box
and add it by clicking Add device in the device view.