6 programming languages, 1 structured text - st, 2 awl / il – Lenze PLC Designer Migration PLC Designer (R2-x)-PLC Designer (R3-x) User Manual
Page 16: 3 fup / fbd, 4 kop / ld, 1 function blocks, 2 blocks with en/eno, Programming languages, Structured text - st, Awl / il

Programming languages
Structured text - ST
16
Lenze · PLC Designer | Migration of V2.x projects · 1.2 EN - 02/2013
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6
Programming languages
This chapter describes the restrictions of the single programming languages when a »PLC Desig-
ner«-V2 project is imported into the »PLC Designer« V3.
6.1
Structured text - ST
No restriction known
6.2
AWL / IL
No restriction known
6.3
FUP / FBD
No restriction known
6.4
KOP / LD
6.4.1
Function blocks
Function blocks may only be used in parallel branches that are directly connected to the power rail.
• Example: Network 1 cannot be imported, network 2 (same function as network 1) can be impor-
ted.
6.4.2
Blocks with EN/ENO
Blocks with EN/ENO must not be provided with any further blocks at the inputs. A variable is per-
mitted.