6

I/O terminals

6.2

Analog terminals

282

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.2.1

Parameterising analog input

By clicking on the

button on the Terminal assignment tab, you reach the parameterising

dialog for the analog input:

Short overview of the parameters for the analog input:

Parameter

Info

Lenze setting

Value Unit

Analog input 1

C00034/1

AIN1: Config.

0: -10V..+10V

C00026/1

AIN1: Offset

0.00 %

C00027/1

AIN1: Gain

1.0000

C00028/1

AIN1: Input voltage

- V

C00029/1

AIN1: Input current

- mA

C00033/1

AIN1: Output value (to application)

- %

C00440/1

PT1 rounding AnalogIn1

10 ms

C00598/1

Resp. to open circuit AIN1

3: TroubleQuickStop

Highlighted in grey = display parameter