C00574 | resp. to brake resist. overtemp, C00579 | resp. to max. speed/output freq. reached, C00580 | resp. to operating system error – Lenze 8400 StateLine User Manual

Page 706: C00574, Tting of, C00580/1, C00579, 15 parameter reference

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00574

706

Lenze · 8400 StateLine · Reference manual · DMS 12.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00574

C00579

C00580

Parameter | Name:

C00574 | Resp. to brake resist. overtemp.

Data type: UNSIGNED_8

Index: 24001

d

= 5DC1

h

Response which is triggered if the threshold set in

C00572

for monitoring brake resistor utilisation is reached.

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00579 | Resp. to max. speed/output freq. reached

Data type: UNSIGNED_8

Index: 23996

d

= 5DBC

h

Response when the max. speed limit (

C00909

) or output frequency limit (

C00910

) has been reached.

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00580 | Resp. to operating system error

Data type: UNSIGNED_8

Index: 23995

d

= 5DBB

h

From version 11.00.00

Response if the required computing time of the application exceeds the available computing time.
Selection list

0 No Reaction
1 Fault
5 Warning

Subcodes

Lenze setting

Info

C00580/1

0: No Reaction

Resp. to runtime exceedance

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1